*Based on designated temper at 65°C +1 bar = 0.1N/mm² = 105 N/m²
Usage: Underground works and heavy duty requirements including hot and cold water supply, gas reticulation, sanitary plumbing, heating and general engineering.
*Based on designated temper at 65°C +1 bar = 0.1N/mm² = 105 N/m²
Usage: Above groundservices including drinking water supply, hot and cold water systems, sanitation, central heating and other general purpose applications.
*Based on material in hard drawn condition at 65°C +1 bar = 0.1N/mm² = 105 N/m²
Usage: Above groundservices including drinking water supply, hot and cold water systems, sanitation, central heating and other general purpose applications.
LOW COST UTILITY RANGE
MECHANICAL PROPERTIES OF TUBE TO EN 1057
Temper
Nom. Dia. (Outside)
MPa*
Minimum Elongation
Hardness**
R220 Annealed
R250 Half Hard
R250 Half Hard
R290 Hard
6 to 54mm
6 to 66.7mm
6 to 159mm
6 to 267mm
220
250
250
290
40%
30% #
20% #
3%
40 to 70
75 to 100
75 to 100
100 min
# Note: Elongations for half hard tubes depend on the ratio of outside diameter to wall thickness.
* MPa: Minimum tensile strength ** Hardness HV/5 indicative